설계 · 접합부

필릿 용접 단위길이당 내력 Fw,Rd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

강구조 필릿 용접의 단위길이당 설계 내력: Fw,Rd = fvw,d · a.

Fw,Rd=fvw,d⋅a\displaystyle F_{w,\mathrm{Rd}} = f_{vw,\mathrm{d}} \cdot a
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

a

Formula and quantities

SymbolNameUnitNote
fvw,d\displaystyle f_{vw,\mathrm{d}}필릿 용접의 설계 전단강도N/m²
a\displaystyle a필릿 용접의 유효 목두께mm
Fw,Rd\displaystyle F_{w,\mathrm{Rd}}단위길이당 설계 용접내력kN/mResult

예제

fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m² · a\displaystyle a = 5 mm

Fw,Rd\displaystyle F_{w,\mathrm{Rd}} = 1,308.65 kN/m

Standard and source

Result
Fw,Rd\displaystyle F_{w,\mathrm{Rd}} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fw,Rd\displaystyle F_{w,\mathrm{Rd}} = 1,308.65 kN/m= (261,730,000 N/m²) · (5 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 접합부에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.