Design · Connections
Bolt design shear resistance Fv,Rd
Design shear resistance per shear plane of a bolt in a steel connection: Fv,Rd = αv · fub · A / γM2.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Shear plane factor (0.6 or 0.5 depending on bolt class and thread) | 1 | ||
| Ultimate tensile strength of bolt | N/m² | ||
| Relevant bolt cross-sectional area (A or A_s) | mm² | ||
| Partial factor for bolted connections | 1 | ||
| Bolt design shear resistance | kN | Result |
Worked example
= 0.6 · = 800,000,000 N/m² · = 245 mm² · = 1.25
= 94.08 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Connections.
Miaknows the formula catalog and asks for what is missing.