設計 · 接合部
すみ肉溶接の単位長さあたり耐力 Fw,Rd
鋼構造すみ肉溶接の単位長さあたり設計耐力: Fw,Rd = fvw,d · a。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| すみ肉溶接の設計せん断強度 | N/m² | ||
| すみ肉溶接の有効のど厚 | mm | ||
| 単位長さあたり設計溶接耐力 | kN/m | Result |
例題
= 261,730,000 N/m² · = 5 mm
= 1,308.65 kN/m
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN/m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 接合部で開始されます。
Miaknows the formula catalog and asks for what is missing.