Design · Masonry

Capacity reduction factor at mid-height of wall (slenderness and eccentricity)

  • Type: Coefficient
  • Version 1
  • reviewed on 11/13/2026

Capacity reduction factor at mid-height of a masonry wall according to Annex G: Φm = A1 · exp(-u² / 2).

Φm=(1−2emkt)⋅exp⁡(−u22)\displaystyle \Phi_{m} = \left(1 - 2\frac{e_{mk}}{t}\right) \cdot \exp\left(-\frac{u^2}{2}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

emkheftΦm

Formula and quantities

SymbolNameUnitNote
emk\displaystyle e_{mk}Design mid-height eccentricitymmemk\displaystyle e_{mk} ≥ 0
t\displaystyle tThickness of wallmmt\displaystyle t > 0
hef\displaystyle h_{\mathrm{ef}}Effective height of wallmmhef\displaystyle h_{\mathrm{ef}} > 0
tef\displaystyle t_{\mathrm{ef}}Effective thickness of wallmmtef\displaystyle t_{\mathrm{ef}} > 0
fk\displaystyle f_{k}Characteristic compressive strength of masonryN/mm²fk\displaystyle f_{k} > 0
E\displaystyle EShort-term modulus of elasticityN/mm²E\displaystyle E > 0
Φm\displaystyle Φ_{m}Mid-height reduction factor–Result

Valid if2⋅emk<t\displaystyle 2 \cdot e_{mk} < t

Worked example

emk\displaystyle e_{mk} = 24 mm · t\displaystyle t = 240 mm · hef\displaystyle h_{\mathrm{ef}} = 2,880 mm · tef\displaystyle t_{\mathrm{ef}} = 240 mm · fk\displaystyle f_{k} = 5 N/mm² · E\displaystyle E = 5,000 N/mm²

Φm\displaystyle Φ_{m} = 0.700185 · Source: hand calculation

Scope and standard

EN 1996-1-1, clause 6.1.2.2 and Annex G (for e_mk < t / 2).

Standard
EN 1996-1-1-2005-a1:2012, clause Annex G, Eq. (G.1)
Result
Φm\displaystyle Φ_{m} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Φm\displaystyle Φ_{m} = 0.700185= (1 - 2 · (24 mm) / (240 mm)) · exp(-0.5 · (max(0; (((2,880 mm) / (240 mm)) · sqrt((5 N/mm²) / (5,000 N/mm²)) - 0.063) / (0.73 - 1.17 · (24 mm) / (240 mm)))) ^ 2)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.