設計 · 組積造構造
壁中央高さの耐力低減係数(細長比および偏心)
附属書 G に基づく組積造壁の中央高さ耐力低減係数:Φm = A1 · exp(-u² / 2)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 中央高さ設計偏心 | mm | ≥ 0 | |
| 壁厚 | mm | > 0 | |
| 壁の有効高さ | mm | > 0 | |
| 壁の有効厚さ | mm | > 0 | |
| 組積造の特性圧縮強度 | N/mm² | > 0 | |
| 短期弾性係数 | N/mm² | > 0 | |
| 中央高さ低減係数 | – | Result |
Valid if
例題
= 24 mm · = 240 mm · = 2,880 mm · = 240 mm · = 5 N/mm² · = 5,000 N/mm²
= 0.700185 · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.1.2.2 および附属書 G(e_mk < t / 2 の場合)。
- Standard
- EN 1996-1-1-2005-a1:2012、付録 G項、式 (G.1)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.