Design · Masonry
Design eccentricity at mid-height of masonry wall
Design eccentricity in the middle fifth of the wall height including creep eccentricity ek, with minimum 0.05 · t.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design bending moment at mid-height of wall | N | ||
| Design vertical load at mid-height of wall | kN/m | > 0 | |
| Eccentricity at mid-height from horizontal loads | mm | ≥ 0 | |
| Initial accidental eccentricity | mm | ≥ 0 | |
| Eccentricity due to creep | mm | ≥ 0 | |
| Thickness of wall | mm | > 0 | |
| Design mid-height eccentricity | mm | Result |
Worked example
= 2,000 N · = 200 kN/m · = 8 mm · = 6 mm · = 3 mm · = 240 mm
= 27 mm · Source: hand calculation
Scope and standard
EN 1996-1-1, clause 6.1.2.2.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 6.1.2.2, Eq. (6.6)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Masonry.
Miaknows the formula catalog and asks for what is missing.