设计 · 砌体
砌体墙中部设计偏心距
墙高中间五分之一区段内包含徐变偏心 ek 的设计偏心距,不小于 0.05 · t。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 墙体中部设计弯矩 | N | ||
| 墙体中部竖向荷载设计值 | kN/m | > 0 | |
| 水平荷载引起的墙体中部偏心距 | mm | ≥ 0 | |
| 初始偶然偏心距 | mm | ≥ 0 | |
| 徐变引起的偏心距 | mm | ≥ 0 | |
| 墙厚 | mm | > 0 | |
| 中部设计偏心距 | mm | Result |
实例
= 2,000 N · = 200 kN/m · = 8 mm · = 6 mm · = 3 mm · = 240 mm
= 27 mm · Source: 手算
Scope and standard
EN 1996-1-1 第 6.1.2.2 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.1.2.2条,式(6.6)
- Result
- in mm