Design · Concrete
Design strength of cracked compressive concrete strut σRd,max
Maximum design compressive stress in concrete struts with transverse tension to EN 1992-1-1 Eq. (6.56): σRd,max = 0.6 · nu' · fcd.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Strength reduction factor (1 - f_ck / 250) | 1 | ||
| Design compressive strength of concrete | N/m² | ||
| Design compressive strength of cracked strut | N/m² | Result |
Worked example
= 0.88 1 · = 17,000,000 N/m²
= 8,976,000 N/m² · Source: EN 1992-1-1:2004 Eq. (6.56)
Scope and standard
Concrete struts in strut-and-tie models with transverse tension to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 6.5.2 (2), Eq. (6.56)
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.