Design · Concrete

Design compressive strength of CCT node σRd,max

  • Type: Resistance
  • Version 1
  • reviewed on 11/12/2026

Maximum design compressive stress in compression-tension nodes with ties in one direction to EN 1992-1-1 Eq. (6.61): σRd,max = 0.85 · nu' · fcd.

σRd,max=0.85⋅ν′⋅fcd\displaystyle \sigma_{\mathrm{Rd},\mathrm{max}} = 0.85 \cdot \nu' \cdot f_{cd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σRd,max

Formula and quantities

SymbolNameUnitNote
ν′\displaystyle \nu'Strength reduction factor (1 - f_ck / 250)1
fcd\displaystyle f_{cd}Design compressive strength of concreteN/m²
σRd,max\displaystyle \sigma_{\mathrm{Rd},\mathrm{max}}Design compressive strength of CCT nodeN/m²Result

Worked example

ν′\displaystyle \nu' = 0.88 1 · fcd\displaystyle f_{cd} = 17,000,000 N/m²

σRd,max\displaystyle \sigma_{\mathrm{Rd},\mathrm{max}} = 12,716,000 N/m² · Source: EN 1992-1-1:2004 Eq. (6.61)

Scope and standard

CCT nodes in strut-and-tie models to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.5.4 (4), Eq. (6.61)
Result
σRd,max\displaystyle \sigma_{\mathrm{Rd},\mathrm{max}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
σRd,max\displaystyle \sigma_{\mathrm{Rd},\mathrm{max}} = 12,716,000 N/m²= 0.85 · (0.88 1) · (17,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.