Design · Concrete

Pure axial compressive resistance NRd

  • Type: Resistance
  • Version 1
  • reviewed on 11/12/2026

Design axial compressive resistance of a reinforced concrete section under pure axial load to EN 1992-1-1 Clause 6.1.

NRd=Ac⋅fcd+As⋅fyd\displaystyle N_{\mathrm{Rd}} = A_{\mathrm{c}} \cdot f_{cd} + A_{s} \cdot f_{yd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRd

Formula and quantities

SymbolNameUnitNote
Ac\displaystyle A_{\mathrm{c}}Cross-sectional area of concretem²
fcd\displaystyle f_{cd}Design compressive strength of concreteN/m²
As\displaystyle A_{s}Total cross-sectional area of longitudinal reinforcementm²
fyd\displaystyle f_{yd}Design yield strength of longitudinal reinforcementN/m²
NRd\displaystyle N_{\mathrm{Rd}}Pure axial compressive resistancekNResult

Worked example

Ac\displaystyle A_{\mathrm{c}} = 0.16 m² · fcd\displaystyle f_{cd} = 17,000,000 N/m² · As\displaystyle A_{s} = 0.002513 m² · fyd\displaystyle f_{yd} = 435,000,000 N/m²

NRd\displaystyle N_{\mathrm{Rd}} = 3,813.16 kN · Source: EN 1992-1-1:2004 clause 6.1

Scope and standard

Reinforced concrete columns and compression members to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.1
Result
NRd\displaystyle N_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRd\displaystyle N_{\mathrm{Rd}} = 3,813.16 kN= (0.16 m²) · (17,000,000 N/m²) + (0.002513 m²) · (435,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.