Design · Concrete

Maximum punching resistance at column perimeter vRd,max

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Maximum punching shear resistance at the column perimeter to EN 1992-1-1 Eq. (6.53).

vRd,max=0.4⋅ν⋅fcd\displaystyle v_{\mathrm{Rd},\mathrm{max}} = 0.4 \cdot \nu \cdot f_{cd}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

vRd,max

Formula and quantities

SymbolNameUnitNote
ν\displaystyle \nuStrength reduction factor for concrete cracked in shear–
fcd\displaystyle f_{cd}Design compressive strength of concreteN/mm²
vRd,max\displaystyle v_{\mathrm{Rd},\mathrm{max}}Maximum punching shear stressN/mm²Result

Worked example

ν\displaystyle \nu = 0.528 · fcd\displaystyle f_{cd} = 17 N/mm²

vRd,max\displaystyle v_{\mathrm{Rd},\mathrm{max}} = 3.5904 N/mm² · Source: EN 1992-1-1:2004 Eq. (6.53)

Scope and standard

Slabs subjected to punching shear to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.4.5 (3), Eq. (6.53)
Result
vRd,max\displaystyle v_{\mathrm{Rd},\mathrm{max}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vRd,max\displaystyle v_{\mathrm{Rd},\mathrm{max}} = 3.5904 N/mm²= 0.4 · 0.528 · (17 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.