Design · Concrete
Maximum punching resistance at column perimeter vRd,max
Maximum punching shear resistance at the column perimeter to EN 1992-1-1 Eq. (6.53).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Strength reduction factor for concrete cracked in shear | – | ||
| Design compressive strength of concrete | N/mm² | ||
| Maximum punching shear stress | N/mm² | Result |
Worked example
= 0.528 · = 17 N/mm²
= 3.5904 N/mm² · Source: EN 1992-1-1:2004 Eq. (6.53)
Scope and standard
Slabs subjected to punching shear to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 6.4.5 (3), Eq. (6.53)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.