Design · Concrete
Maximum prestressing jacking force Pmax (EN 1992-1-1)
Maximum prestressing force applied to a tendon during tensioning according to EN 1992-1-1 Clause 5.10.2.1(1) Eq. (5.41): Pmax = Ap · σp,max.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Cross-sectional area of prestressing tendon | mm² | ||
| Maximum allowable tendon stress at jacking | N/m² | ||
| Maximum jacking force | kN | Result |
Worked example
= 1,800 mm² · = 1,488,000,000 N/m²
= 2,678.4 kN
Standard and source
- Standard
- EN 1992-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.