Design · Concrete
Maximum torsional resistance TRd,max
Maximum design torsional resistance governed by compression strut capacity to EN 1992-1-1 Eq. (6.30).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Strength reduction factor for concrete cracked in shear | – | ||
| Coefficient for normal stress state | – | ||
| Design compressive strength of concrete | N/mm² | ||
| Area enclosed by the centerlines of the connecting walls | mm² | ||
| Effective wall thickness | mm | ||
| Sine of strut angle | – | ||
| Cosine of strut angle | – | ||
| Maximum torsional resistance | Nm | Result |
Worked example
= 0.528 · = 1 · = 17 N/mm² · = 120,000 mm² · = 100 mm · = 0.7071 · = 0.7071
= 107,710 Nm · Source: EN 1992-1-1:2004 Eq. (6.30)
Scope and standard
Concrete beams subjected to torsion according to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 6.3.2 (4), Eq. (6.30)
- Result
- in kN*m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.