Design · Concrete

Effective buckling length for unbraced column l0

  • Type: Property
  • Version 1
  • reviewed on 11/12/2026

Effective buckling length of an unbraced compression member in a sway frame to EN 1992-1-1 Eq. (5.16).

l0=l⋅max⁡(1+10⋅k1⋅k2k1+k2,(1+k11+k1)⋅(1+k21+k2))\displaystyle l_{0} = l \cdot \max\left(\sqrt{1 + 10 \cdot \frac{k_{1} \cdot k_{2}}{k_{1} + k_{2}}}, \left(1 + \frac{k_{1}}{1 + k_{1}}\right) \cdot \left(1 + \frac{k_{2}}{1 + k_{2}}\right)\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ll0

Formula and quantities

SymbolNameUnitNote
l\displaystyle lClear height of compression memberm
k1\displaystyle k_{1}Relative flexibility of rotational restraint at end 11
k2\displaystyle k_{2}Relative flexibility of rotational restraint at end 21
l0\displaystyle l_{0}Effective buckling lengthmResult

Worked example

l\displaystyle l = 3.5 m · k1\displaystyle k_{1} = 0.5 1 · k2\displaystyle k_{2} = 0.5 1

l0\displaystyle l_{0} = 6.5479 m · Source: EN 1992-1-1:2004 Eq. (5.16)

Scope and standard

Unbraced reinforced concrete frame columns to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 5.8.3.2 (3), Eq. (5.16)
Result
l0\displaystyle l_{0} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
l0\displaystyle l_{0} = 6.5479 m= (3.5 m) · max(sqrt(1 + 10 · (0.5 1) · (0.5 1) / ((0.5 1) + (0.5 1))); (1 + (0.5 1) / (1 + (0.5 1))) · (1 + (0.5 1) / (1 + (0.5 1))))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.