Utilization ratio of a composite column under combined axial compression and uniaxial bending according to EN 1994-1-1 Clause 6.7.3.6 Eq. (6.46): η = MEd / (αM · μd · Mpl,Rd).

η=MEd/(αM⋅μd⋅Mpl,Rd)\displaystyle \eta = M_{\mathrm{Ed}} / (\alpha _{M} \cdot \mu _{\mathrm{d}} \cdot M_{\mathrm{pl},\mathrm{Rd}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

MEdηMplRd

Formula and quantities

SymbolNameUnitNote
MEd\displaystyle M_{\mathrm{Ed}}Design bending moment including second-order effectskNm
αM\displaystyle \alpha_{M}Steel grade factor (0.9 for S235–S355, 0.8 for S420–S460)1
μd\displaystyle \mu_{\mathrm{d}}Moment resistance ratio from interaction curve1
Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}}Plastic moment resistance of composite columnkNm
η\displaystyle \etaCombined bending utilization ratio (<= 1.0)1Result

Worked examples

S355 column

MEd\displaystyle M_{\mathrm{Ed}} = 180 kNm · αM\displaystyle \alpha_{M} = 0.9 · μd\displaystyle \mu_{\mathrm{d}} = 0.85 · Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 300 kNm

η\displaystyle \eta = 0.784314

S460 column

MEd\displaystyle M_{\mathrm{Ed}} = 220 kNm · αM\displaystyle \alpha_{M} = 0.8 · μd\displaystyle \mu_{\mathrm{d}} = 0.9 · Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 380 kNm

η\displaystyle \eta = 0.804094

Standard and source

Standard
EN 1994-1-1:2004, clause 6.7.3.6, Eq. (6.46)
Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.784314 1= (180 kNm) / ((0.9 1) · (0.85 1) · (300 kNm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.