Design · Composite

Bending resistance with partial shear connection MRd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Conservative linear interpolation of bending moment resistance for ductile shear connectors: MRd = Mpl,a,Rd + (Mpl,Rd - Mpl,a,Rd) · eta.

MRd=Mpl,a,Rd+(Mpl,Rd−Mpl,a,Rd)⋅η\displaystyle M_{\mathrm{Rd}} = M_{\mathrm{pl},a,\mathrm{Rd}} + (M_{\mathrm{pl},\mathrm{Rd}} - M_{\mathrm{pl},a,\mathrm{Rd}}) \cdot \eta
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

MRdη

Formula and quantities

SymbolNameUnitNote
Mpl,a,Rd\displaystyle M_{\mathrm{pl},a,\mathrm{Rd}}Plastic bending resistance of steel section alonekNm
Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}}Plastic bending resistance with full shear connectionkNm
η\displaystyle \etaDegree of shear connection1
MRd\displaystyle M_{\mathrm{Rd}}Design bending resistance with partial shear connectionkNmResult

Worked example

Mpl,a,Rd\displaystyle M_{\mathrm{pl},a,\mathrm{Rd}} = 360 kNm · Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 680 kNm · η\displaystyle \eta = 0.65

MRd\displaystyle M_{\mathrm{Rd}} = 568 kNm

Standard and source

Result
MRd\displaystyle M_{\mathrm{Rd}} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MRd\displaystyle M_{\mathrm{Rd}} = 568 kNm= (360 kNm) + ((680 kNm) - (360 kNm)) · (0.65 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.