설계 · 복합
강재 기여비 δ
합성 기둥의 전체 소성 저항에 대한 구조용 강재 소성 저항의 비(간편법 조건 0.2 <= delta <= 0.9): δ = (Aa · fyd) / Npl,Rd.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 구조용 강재 단면적 | cm² | ||
| 구조용 강재의 설계 항복 강도 | N/m² | ||
| 합성 기둥의 설계 소성 저항 | kN | ||
| 강재 기여비 | 1 | Result |
예제
= 118.4 cm² · = 355,000,000 N/m² · = 7,247.3 kN
= 0.58
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 복합에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.