Plastic compressive resistance of concrete flange Ncf
Design plastic compressive resistance of the effective concrete flange: Ncf = 0.85 · fcd · beff · hc.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design value of concrete compressive strength | N/m² | ||
| Total effective width of concrete flange | mm | ||
| Thickness of concrete flange above ribs | mm | ||
| Plastic compressive resistance of concrete flange | kN | Result |
Worked example
= 20,000,000 N/m² · = 2,000 mm · = 120 mm
= 4,080 kN
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.