细长墙体中部由徐变引起的附加偏心距:ek = 0.002 · φinf · (hef / tef) · √(t · em)。

ek=0.002⋅φ∞⋅heftef⋅t⋅em\displaystyle e_{k} = 0.002 \cdot \varphi_\infty \cdot \frac{h_{\mathrm{ef}}}{t_{\mathrm{ef}}} \cdot \sqrt{t \cdot e_{m}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ekheft

Formula and quantities

SymbolNameUnitNote
φ∞\displaystyle φ_∞最终徐变系数–φ∞\displaystyle φ_∞ ≥ 0
hef\displaystyle h_{\mathrm{ef}}墙体计算高度mmhef\displaystyle h_{\mathrm{ef}} > 0
tef\displaystyle t_{\mathrm{ef}}墙体有效厚度mmtef\displaystyle t_{\mathrm{ef}} > 0
t\displaystyle t墙厚mmt\displaystyle t > 0
em\displaystyle e_{m}墙体中部一阶偏心距(不含徐变)mmem\displaystyle e_{m} ≥ 0
ek\displaystyle e_{k}徐变偏心距mmResult

实例

φ∞\displaystyle φ_∞ = 1.5 · hef\displaystyle h_{\mathrm{ef}} = 3,000 mm · tef\displaystyle t_{\mathrm{ef}} = 200 mm · t\displaystyle t = 200 mm · em\displaystyle e_{m} = 20 mm

ek\displaystyle e_{k} = 2.84605 mm · Source: 手算

Scope and standard

EN 1996-1-1 第 6.1.2.2 条(高厚比低于 lambda_c 时为零)。

Standard
EN 1996-1-1-2005-a1:2012,第6.1.2.2条,式(6.8)
Result
ek\displaystyle e_{k} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ek\displaystyle e_{k} = 2.84605 mm= 0.002 · 1.5 · ((3,000 mm) / (200 mm)) · sqrt((200 mm) · (20 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 砌体 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.