設計 · 組積造構造
組積造壁のクリープ偏心
細長い壁の中央高さにおけるクリープによる付加偏心:ek = 0.002 · φinf · (hef / tef) · √(t · em)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 最終クリープ係数 | – | ≥ 0 | |
| 壁の有効高さ | mm | > 0 | |
| 壁の有効厚さ | mm | > 0 | |
| 壁厚 | mm | > 0 | |
| 中央高さにおける一次偏心(クリープ除く) | mm | ≥ 0 | |
| クリープ偏心 | mm | Result |
例題
= 1.5 · = 3,000 mm · = 200 mm · = 200 mm · = 20 mm
= 2.84605 mm · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.1.2.2(細長比が lambda_c 未満の場合はゼロ)。
- Standard
- EN 1996-1-1-2005-a1:2012、6.1.2.2項、式 (6.8)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.