Direct crack width
Steel stress in the cracked section, effective tension height hc,ef, crack spacing sr,max, and wk under the quasi-permanent combination to EN 1992-1-1 7.3.4, with the German NA rule for sr,max.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000086 · Skill
EN 1992-1-1:2004+AC:2010, 7.3.1 to 7.3.4DIN EN 1992-1-1/NA:2013-04+A1:2015-12ACI 318-19, 24.3Enter the section, concrete, reinforcement, exposure class, and the quasi-permanent moment or tension force. Mia calculates the crack width wk with the full calculation path, checks the minimum reinforcement As,min against the provided bars, and, for ACI 318, the bar spacing.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check the crack width of a 300×600 mm beam, C30/37, B500, 4 Ø20 bottom in one layer, nominal cover 35 mm to Ø10 stirrups, quasi-permanent moment 120 kNm, exposure XC3, long-term loading, external restraint, to EN 1992-1-1:2004+AC:2010 with DIN EN 1992-1-1/NA:2013-04+A1:2015-12.
Quasi-permanent combination, long-term loading (kt = 0.4). German NA: sr,max to Eq. (7.11DE), fct,eff = 3.0 MPa for As,min, σs for As,min from the footnote of Table 7.2DE.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Steel stress in the cracked section, effective tension height hc,ef, crack spacing sr,max, and wk under the quasi-permanent combination to EN 1992-1-1 7.3.4, with the German NA rule for sr,max.
kc, k, fct,eff (at least 3 MPa under the German NA), and σs from Table 7.2N or 7.2DE to EN 1992-1-1 7.3.2, compared with the provided reinforcement.
Limiting bar diameter from Table 7.2N or 7.2DE to EN 1992-1-1 7.3.3, with the Table 7.3N bar spacing for information.
Maximum bar spacing to ACI 318-19 and 318-25, 24.3, and the design crack width wd to fib Model Code 2010, 7.6.4, marked as a secondary source in every answer.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1992-1-1:2011-01 (EN 1992-1-1:2004 + AC:2010) + DIN EN 1992-1-1/A1:2015-03
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1992-1-1/NA:2013-04 + DIN EN 1992-1-1/NA/A1:2015-12Current | DIN Media | |
| EN | Recommended valuesEN 1992-1-1:2004 + AC:2010 + A1:2014 | – |
Status checked on
Frequently asked questions
The design code with edition and National Annex, the section, concrete class, exposure class, tension bars with cover and stirrup diameter, and the quasi-permanent moment or tension force. Mia asks for a missing input with a form.
Mia limits the crack spacing sr,max with Eq. (7.11DE), uses fct,eff of at least 3 MPa for the minimum reinforcement, and takes σs for As,min from the footnote of Table 7.2DE.
Yes. Mia first asks for the provided bars, so that As,min is checked against them. Without provided bars, As,min is reported as a value.
No. ACI 318 controls cracking by the spacing of the reinforcement closest to the tension face (24.3), so Mia reports the maximum bar spacing and its utilization, not a crack width.
Not by this skill. Solid circular sections and bored piles to EN 1992-1-1 are checked by the separate skill for circular sections.
Start with the example and adapt it to your structural system.
New calculation