EN 1992-1-1:2004+AC:2010, 6.8.1 to 6.8.3, 6.8.5, 6.8.6, 6.8.7DIN EN 1992-1-1/NA:2013-04+A1:2015-12EN 1992-2:2005+AC:2008, Annex NN

Fatigue check of reinforced concrete to Eurocode 2

Enter the section, the provided reinforcement, and the upper and lower internal forces, or read them from your RFEM 6 model. Mia checks the reinforcing steel, the stirrups, the concrete compression zone, and the compression strut at level 1 or level 2 and shows each stress range with its clause.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

300×600 mm · C30/37 · 4 Ø20 · level 1

All level 1 fatigue checks fulfilled
300×600 mm · C30/37 · 4 Ø20 · level 1
Section
300 × 600 mm · C30/37
Reinforcement
4 Ø20 bottom · 2 Ø12 top · c = 45 mm
Stirrups
asw = 785 mm²/m · cot θ = 1.75
Internal forces
My = 110 / 75 kNm · Vz = 90 / 60 kN
Code
EN 1992-1-1, recommended values, level 1

Fatigue check level 1 to EN 1992-1-1:2004+AC:2010 with the recommended values. Beam b = 300 mm, h = 600 mm, C30/37, bottom bars 4 Ø20 straight, top bars 2 Ø12, clear cover 45 mm, stirrups asw = 785 mm²/m (Ø10 / 200 mm, two legs), cot θ = 1.75, first cyclic loading at 28 days, cement class N. Frequent combination My = 110 / 75 kNm, Vz = 90 / 60 kN, N = 0.

Key results

Bottom reinforcement Δσs
57.06 MPa ≤ 70 MPa (η = 0.82)
Stirrups Δσsw
58.90 MPa ≤ 70 MPa (η = 0.84)
Concrete top σc,max
8.24 MPa (η = 0.82)
Compression strut σcd,max
1.27 MPa (η = 0.29)
Governing utilization
η = 0.84 (stirrups)

Deterministic values of the calculation core for the stated inputs; cracked section with αe = 10, z = 0.9 d = 490.5 mm, θfat from Eq. (6.65).

  • — Effective depth d = 545 mm from h = 600 mm, clear cover 45 mm, and Ø20 bars.
  • — fcd,fat = 14.96 MPa (Eq. (6.76), t0 = 28 days, cement class N).
  • — The top bars lie in the compression zone; their stress range is not checked.

Required inputs

  • Code: EN 1992-1-1 with recommended values or the German National Annex, or fib Model Code 2010
  • Verification level: 1 (simplified) or 2 (damage equivalent stress range)
  • Member or 1 m slab strip, section b × h, concrete strength fck
  • Bottom and top reinforcement with bar diameter and clear cover, stirrups asw with cot θ of the ULS design
  • Upper and lower state My, N, and Vz (frequent combination at level 1, fatigue combination at level 2)

What you receive

  • Governing check and utilization
  • Stress ranges of the bottom and top reinforcement
  • Stirrup stress range and compression strut
  • Concrete stresses and fcd,fat
  • Calculation table with formula, value, unit, and clause
  • Notes, assumptions, and excluded cases
Reviewed calculation example

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Fatigue of reinforced concrete | code and inputs
Structural calculation to standard

System sketch

All required fields completed

Inputs completeReady to calculate

What this skill checks

Reinforcing steel

Stress range of each reinforcement layer from the cracked section (state II), checked against k1 at level 1 (6.8.6) or the damage equivalent stress range at level 2 (6.8.5).

Shear reinforcement

Stirrup stress range with the fatigue strut angle of Eq. (6.65); for a shear sign change either the signed range (default) or stirrups in tension only.

Concrete

Compression zone and compression strut to 6.8.7(2) or 6.8.7(1), with fcd,fat from the concrete age at the first cyclic loading.

Required reinforcement

On request, the longitudinal and shear reinforcement that the fatigue checks require, with bar proposals.