Biaxial bending interaction
Resolves gravity and wind loads into strong-axis M_y and weak-axis M_z from the roof slope and the web orientation, then runs the EN 1993-1-1 6.2.9.1 interaction check.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000010 · Skill
EN 1990EN 1993-1-1EN 1993-1-1:6.2.9Provide the roof slope, span, section, steel grade, characteristic loads, and deflection limit. Mia resolves the biaxial bending, runs EN 1993-1-1 ULS and SLS checks, reports the governing utilisation, and can prepare an RFEM comparison file.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Ridge-parallel simply supported purlin, IPE 200, S235, roof slope 25°, span 5.0 m, spacing 4.0 m along the roof, web perpendicular to the roof. Loads: gk = 0.6 kN/m², roof snow sk = 0.8 kN/m² on plan, wind pressure qw,p = 0.4 kN/m², wind suction qw,s = 0.5 kN/m². Top flange continuously restrained by trapezoidal sheeting, deflection limit L/200. Run the check.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Resolves gravity and wind loads into strong-axis M_y and weak-axis M_z from the roof slope and the web orientation, then runs the EN 1993-1-1 6.2.9.1 interaction check.
Checks lateral-torsional buckling with the M_cr load point at the destabilising edge (EN 1993-1-1 6.3.2) and the 6.3.3 interaction with Annex B, Table B.2, for gravity and wind uplift.
Forms ULS and SLS combinations from g_k, roof snow s_k, wind pressure, and wind suction, with the partial factors of the selected National Annex (EN, DE, AT, CZ).
Classifies the section by c/t ratios and verifies shear, bending, and combined M_y + M_z resistance using section properties fetched from profile data.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1993-1-1:2010-12 (EN 1993-1-1:2005 + AC:2009) + DIN EN 1993-1-1/A1:2014-07
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1993-1-1/NA:2022-10WithdrawnNewer edition: DIN EN 1993-1-1/NA:2026-04 | γM0 = 1.00γM1 = 1.10 | DIN Media |
| AT | ÖNORM B 1993-1-1:2017-11-01Current | γM0 = 1.00γM1 = 1.00 | Austrian Standards |
| CZ | ČSN EN 1993-1-1 ed. 2 (73 1401):2011-07 + A1 + Z1, NACurrentNewer edition: ČSN EN 1993-1-1 ed. 3 (73 1401) | γM0 = 1.00γM1 = 1.00 | shop.normy.biz |
| EN | Recommended valuesEN 1993-1-1:2005 + AC:2009 + A1:2014 | γM0 = 1.00γM1 = 1.00 | – |
Status checked on
Edition used: DIN EN 1990:2021-10 (EN 1990:2002 + A1:2005 + A1:2005/AC:2010)
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1990/NA:2010-12 + DIN EN 1990/NA/A1:2024-05Current | γG = 1.35γQ = 1.50 | DIN Media |
| EN | Recommended valuesEN 1990:2002 + A1:2005 + A1:2005/AC:2010 | γG = 1.35γQ = 1.50 | – |
Status checked on
Frequently asked questions
This skill handles ridge-parallel purlins on sloped roofs, where the roof slope creates biaxial bending (My + Mz). The single-span beam skill covers straight beams with uniaxial bending only.
Wind suction is treated as uplift, which can reverse which flange is in compression. Mia checks whether the assumed lateral restraint still applies to the compression flange under uplift and flags the governing LTB case.
If no country is stated, Mia applies the EN partial factors (γM0 = 1.00, γM1 = 1.00) and names the row used. For Germany, Austria, or the Czech Republic, Mia applies the partial factors of the respective National Annex. The deflection limit is chosen by you, independently of the National Annex.
No. This skill covers single-span simply supported purlins only. For continuous beams over two or more spans, use the two-span beam design skill or the RFEM model design skill.
Start with the example and adapt it to your structural system.
New calculation