設計 · 組積造構造
組積造の集中荷重に対する設計耐力
集中荷重を受ける組積造壁の設計鉛直耐力:NRdc = β · Ab · fd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 集中荷重割増係数 | – | ≥ 1, ≤ 1.5 | |
| 載荷支圧面積 | mm² | > 0 | |
| 組積造の設計圧縮強度 | N/mm² | > 0 | |
| 集中荷重に対する設計耐力 | kN | Result |
例題
= 1.35 · = 48,000 mm² · = 3 N/mm²
= 194.4 kN · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.1.3.
- Standard
- EN 1996-1-1-2005-a1:2012、6.1.3項、式 (6.9)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.