Design · Timber

Effective residual timber depth for 3-sided fire (EN 1995-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Effective residual cross-section depth of a rectangular timber beam exposed to fire on three sides (bottom and sides) according to EN 1995-1-2 Clause 4.2.2: hef = h - def.

hef=h−def\displaystyle h_{\mathrm{ef}} = h - d_{\mathrm{ef}}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdefhef

Formula and quantities

SymbolNameUnitNote
h\displaystyle hOriginal timber section depthmm
def\displaystyle d_{\mathrm{ef}}Effective charring depthmm
hef\displaystyle h_{\mathrm{ef}}Effective residual depthmmResult

Worked example

h\displaystyle h = 400 mm · def\displaystyle d_{\mathrm{ef}} = 49 mm

hef\displaystyle h_{\mathrm{ef}} = 351 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
hef\displaystyle h_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
hef\displaystyle h_{\mathrm{ef}} = 351 mm= (400 mm) - (49 mm)

Continue with Mia