Design · Steel
Web resistance to transverse patch loading FRd (EN 1993-1-5)
Design resistance of a web to local transverse forces (patch loading) according to EN 1993-1-5 Clause 6.2(1): FRd = fyw · χF · ly · tw / γM1.
- EN 1993-1-5:2006
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Web steel yield strength | N/m² | ||
| Patch loading reduction factor | 1 | ||
| Effective loaded length | mm | ||
| Web thickness | mm | ||
| Partial factor gamma_M1 | 1 | ||
| Design patch loading resistance | kN | Result |
Worked example
= 355,000,000 N/m² · = 0.65 · = 340 mm · = 10 mm · = 1.1
= 713.227 kN
Standard and source
- Standard
- EN 1993-1-5:2006
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.