Design · Steel

Shear area of welded I-section parallel to web Av

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Shear area of welded I-section load parallel to web according to EN 1993-1-1 6.2.6(3)d: Av = η · hw · tw.

Av=η⋅hw⋅tw\displaystyle A_{v} = \eta \cdot h_{w} \cdot t_{w}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
η\displaystyle \etaShear area coefficient eta1
hw\displaystyle h_{w}Clear depth of webmm
tw\displaystyle t_{w}Web thicknessmm
Av\displaystyle A_{v}Shear area A_vmm²Result

Worked example

η\displaystyle \eta = 1 · hw\displaystyle h_{w} = 400 mm · tw\displaystyle t_{w} = 8 mm

Av\displaystyle A_{v} = 3,200 mm²

Standard and source

Result
Av\displaystyle A_{v} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Av\displaystyle A_{v} = 3,200 mm²= (1 1) · (400 mm) · (8 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.