Value of ΦLT for determining the lateral-torsional buckling reduction factor: ΦLT = 0.5 · (1 + αLT · (λ̄LT - 0.2) + λ̄LT²).

ΦLT=0.5⋅[1+αLT⋅(λˉLT−0.2)+λˉLT2]\displaystyle \Phi_{\mathrm{LT}} = 0.5 \cdot \left[1 + \alpha_{\mathrm{LT}} \cdot (\bar{\lambda}_{\mathrm{LT}} - 0.2) + \bar{\lambda}_{\mathrm{LT}}^2\right]
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λLT

Formula and quantities

SymbolNameUnitNote
αLT\displaystyle \alpha_{\mathrm{LT}}Imperfection factor for LTB–
λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}}Non-dimensional slenderness for LTB–
ΦLT\displaystyle \Phi_{\mathrm{LT}}LTB curve parameter Phi_LT–Result

Worked example

αLT\displaystyle \alpha_{\mathrm{LT}} = 0.34 · λˉLT\displaystyle \bar{\lambda}_{\mathrm{LT}} = 0.9607

ΦLT\displaystyle \Phi_{\mathrm{LT}} = 1.0908 · Source: EN 1993-1-1:2005 Eq. (6.56)

Scope and standard

General lateral-torsional buckling formulation according to EN 1993-1-1, clause 6.3.2.2.

Standard
EN 1993-1-1:2005, clause 6.3.2.2 (1), Eq. (6.56)
Result
ΦLT\displaystyle \Phi_{\mathrm{LT}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

ΦLT\displaystyle \Phi_{\mathrm{LT}} = 1.09079= 0.5 · (1 + 0.34 · (0.9607 - 0.2) + 0.9607²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.