Design · Connections

T-stub Mode 1 tension resistance FT,1,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design tension resistance of an equivalent T-stub flange for Mode 1 (complete yielding of flange): FT,1,Rd = 4 · Mpl,1,Rd / m.

FT,1,Rd=4⋅Mpl,1,Rd/m\displaystyle F_{T,1,\mathrm{Rd}} = 4 \cdot M_{\mathrm{pl},1,\mathrm{Rd}} / m
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FT1RdmMpl1Rd

Formula and quantities

SymbolNameUnitNote
Mpl,1,Rd\displaystyle M_{\mathrm{pl},1,\mathrm{Rd}}Plastic moment resistance of T-stub flange (Mode 1)Nm
m\displaystyle mDistance from bolt centreline to plastic hinge linemm
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}}T-stub Mode 1 tension resistancekNResult

Worked example

Mpl,1,Rd\displaystyle M_{\mathrm{pl},1,\mathrm{Rd}} = 3,150 Nm · m\displaystyle m = 35 mm

FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} = 360 kN

Standard and source

Result
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
FT,1,Rd\displaystyle F_{T,1,\mathrm{Rd}} = 360 kN= 4 · (3,150 Nm) / (35 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.