T-stub flange plastic moment resistance Mpl,Rd
Plastic moment resistance of an equivalent T-stub flange per effective length leff: Mpl,Rd = 0.25 · leff · tf² · fy / γM0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Effective length of equivalent T-stub | mm | ||
| Thickness of T-stub flange or end plate | mm | ||
| Yield strength of flange or end plate | N/m² | ||
| Partial factor for cross-section resistance | 1 | ||
| T-stub flange plastic moment resistance | Nm | Result |
Worked example
= 210 mm · = 16 mm · = 235,000,000 N/m² · = 1
= 3,160 Nm
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN*m