Design · Connections

T-stub flange plastic moment resistance Mpl,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Plastic moment resistance of an equivalent T-stub flange per effective length leff: Mpl,Rd = 0.25 · leff · tf² · fy / γM0.

Mpl,Rd=0.25⋅leff⋅tf2⋅fy/γM0\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 0.25 \cdot l_{\mathrm{eff}} \cdot t_{f}^2 \cdot f_{y} / \gamma _{\mathrm{M0}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

tfleffMplRd

Formula and quantities

SymbolNameUnitNote
leff\displaystyle l_{\mathrm{eff}}Effective length of equivalent T-stubmm
tf\displaystyle t_{f}Thickness of T-stub flange or end platemm
fy\displaystyle f_{y}Yield strength of flange or end plateN/m²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor for cross-section resistance1
Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}}T-stub flange plastic moment resistanceNmResult

Worked example

leff\displaystyle l_{\mathrm{eff}} = 210 mm · tf\displaystyle t_{f} = 16 mm · fy\displaystyle f_{y} = 235,000,000 N/m² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 3,160 Nm

Standard and source

Result
Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} in kN*m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Mpl,Rd\displaystyle M_{\mathrm{pl},\mathrm{Rd}} = 3,158.4 Nm= 0.25 · (210 mm) · (16 mm)² · (235,000,000 N/m²) / (1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.