Design · Connections

Column web panel shear resistance Vwp,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design plastic shear resistance of an unstiffened column web panel in a beam-to-column joint: Vwp,Rd = 0.9 · fy,wc · Avc / (√(3) · γM0).

Vwp,Rd=0.9⋅fy,wc⋅Avc/(3⋅γM0)\displaystyle V_{wp,\mathrm{Rd}} = 0.9 \cdot f_{y,wc} \cdot A_{vc} / (\sqrt{3} \cdot \gamma _{\mathrm{M0}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
fy,wc\displaystyle f_{y,wc}Yield strength of column webN/m²
Avc\displaystyle A_{vc}Shear area of columncm²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor for cross-section resistance1
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}}Column web panel shear resistancekNResult

Worked example

fy,wc\displaystyle f_{y,wc} = 355,000,000 N/m² · Avc\displaystyle A_{vc} = 33.2 cm² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} = 612.42 kN

Standard and source

Result
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} = 612.419 kN= 0.9 · (355,000,000 N/m²) · (33.2 cm²) / (sqrt(3) · (1 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.