Design · Connections
Column web transverse tension resistance Ft,wc,Rd
Design resistance of an unstiffened column web in transverse tension: Ft,wc,Rd = ω · beff,t,wc · twc · fy,wc / γM0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Reduction factor for interaction with shear in column web panel | 1 | ||
| Effective width of column web in tension | mm | ||
| Thickness of column web | mm | ||
| Yield strength of column web | N/m² | ||
| Partial factor for cross-section resistance | 1 | ||
| Column web tension resistance | kN | Result |
Worked example
= 0.85 · = 160 mm · = 10 mm · = 355,000,000 N/m² · = 1
= 482.8 kN
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Connections.
Miaknows the formula catalog and asks for what is missing.