Diseño · Acero

Resistencia de diseño a cortante de elemento de acero en incendio (EN 1993-1-2)

  • Tipo: Resistencia
  • Versión 1
  • revisado el 21/11/2026

Resistencia de diseño a cortante de una sección de acero a temperatura elevada según EN 1993-1-2 cláusula 4.2.3.3 Ec. (4.16): VfitRd = (ky · Av · fy) / (√(3) · γMfi).

Vfi,t,Rd=ky,Θ⋅Av⋅fy3⋅γM,fi\displaystyle V_{fi,t,\mathrm{Rd}} = \frac{k_{y,\Theta} \cdot A_{v} \cdot f_{y}}{\sqrt{3} \cdot \gamma_{M,fi}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ky\displaystyle k_{y}Factor de reducción del límite elástico a la temperatura del alma1
Av\displaystyle A_{v}Área de cortante de la sección de aceromm²
fy\displaystyle f_{y}Límite elástico del acero a 20 °CN/m²
γMfi\displaystyle \gamma_{Mfi}Coeficiente parcial para acero en incendio (normalmente 1,0)1
VfitRd\displaystyle V_{fitRd}Resistencia de diseño a cortante en incendiokNResult

Ejemplo resuelto

ky\displaystyle k_{y} = 0,78 1 · Av\displaystyle A_{v} = 2568 mm² · fy\displaystyle f_{y} = 355.000.000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1

VfitRd\displaystyle V_{fitRd} = 410,54 kN

Standard and source

Standard
EN 1993-1-2:2005
Result
VfitRd\displaystyle V_{fitRd} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VfitRd\displaystyle V_{fitRd} = 410,542 kN= ((0,78 1) · (2568 mm²) · (355.000.000 N/m²)) / (sqrt(3) · (1 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La búsqueda comienza en Diseño › Acero.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.