Geotechnics · Earth pressure
Ground anchor bond length Lbond
Required grout body bond length of a ground anchor: Lbond = Rak / (π · d · qsk).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic pullout resistance of anchor | kN | ||
| Borehole diameter of anchor grout body | m | ||
| Characteristic skin friction between grout and soil | N/m² | ||
| Required anchor bond length | m | Result |
Worked example
= 300 kN · = 0.15 m · = 100,000 N/m²
= 6.3662 m · Source: EN 1997-1:2004 clause 8.5.2
Scope and standard
Design of grouted ground anchors according to EN 1997-1 Clause 8.5.2.
- Standard
- EN 1997-1:2004, clause 8.5.2, Eq. (8.2)
- Result
- in m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Geotechnics › Earth pressure.