Geotechnics · Earth pressure

Ground anchor design pullout resistance Ra,d

  • Type: Resistance
  • Version 1
  • reviewed on 11/12/2026

Design pullout resistance of a grouted ground anchor: Rad = Rak / γa.

Ra,d=Ra,kγa\displaystyle R_{a,\mathrm{d}} = \frac{R_{a,k}}{\gamma_{a}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ra,d

Formula and quantities

SymbolNameUnitNote
Ra,k\displaystyle R_{a,k}Characteristic pullout resistance of anchorkN
γa\displaystyle \gamma_{a}Partial factor for anchor pullout resistance–
Ra,d\displaystyle R_{a,\mathrm{d}}Design pullout resistance of anchorkNResult

Worked example

Ra,k\displaystyle R_{a,k} = 350 kN · γa\displaystyle \gamma_{a} = 1.1

Ra,d\displaystyle R_{a,\mathrm{d}} = 318.18 kN · Source: EN 1997-1:2004 clause 8.5.1

Scope and standard

Ground anchor design according to EN 1997-1 Clause 8.5.1.

Standard
EN 1997-1:2004, clause 8.5.1, Eq. (8.1)
Result
Ra,d\displaystyle R_{a,\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ra,d\displaystyle R_{a,\mathrm{d}} = 318.182 kN= (350 kN) / 1.1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Earth pressure.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.