Geotechnics · Bearing resistance

Shape factor sgamma for rectangular foundations

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Shape factor for self-weight term: sγ = 1 - 0.3 · (B' / L').

sγ=1−0,3⋅(B′L′)\displaystyle s_\gamma = 1 - 0{,}3 \cdot \left(\frac{B'}{L'}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzB'L'

Formula and quantities

SymbolNameUnitNote
B′\displaystyle B'Effective foundation widthm
L′\displaystyle L'Effective foundation lengthm
sγ\displaystyle s_\gammaShape factor s_gamma–Result

Worked example

B′\displaystyle B' = 2 m · L′\displaystyle L' = 3 m

sγ\displaystyle s_\gamma = 0.8 · Source: EN 1997-1:2004 Annex D

Scope and standard

Rectangular shallow foundations according to EN 1997-1, Annex D.

Standard
EN 1997-1:2004, clause D.4, Eq. (D.3)
Result
sγ\displaystyle s_\gamma (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
sγ\displaystyle s_\gamma = 0.8= 1 - 0.3 · ((2 m) / (3 m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Bearing resistance.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.