Geotechnics · Bearing resistance

Shape factor sc for rectangular foundations

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Shape factor for cohesion term: sc = (sq · Nq - 1) / (Nq - 1).

sc=sq⋅Nq−1Nq−1\displaystyle s_{\mathrm{c}} = \frac{s_{q} \cdot N_{q} - 1}{N_{q} - 1}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

sc

Formula and quantities

SymbolNameUnitNote
sq\displaystyle s_{q}Shape factor for surcharge–
Nq\displaystyle N_{q}Bearing capacity factor for surcharge–
sc\displaystyle s_{\mathrm{c}}Shape factor s_c–Result

Worked example

sq\displaystyle s_{q} = 1.33333 · Nq\displaystyle N_{q} = 18.4011

sc\displaystyle s_{\mathrm{c}} = 1.35249 · Source: EN 1997-1:2004 Annex D

Scope and standard

Rectangular shallow foundations according to EN 1997-1, Annex D.

Standard
EN 1997-1:2004, clause D.4, Eq. (D.3)
Result
sc\displaystyle s_{\mathrm{c}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

sc\displaystyle s_{\mathrm{c}} = 1.35249= (1.33333 · 18.4011 - 1) / (18.4011 - 1)