Geotechnics · Bearing resistance
Shape factor sq for rectangular foundations
Shape factor for surcharge term: sq = 1 + (B' / L') · sin(phi').
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Effective foundation width | m | ||
| Effective foundation length | m | ||
| Effective friction angle of soil | ° | ||
| Shape factor s_q | – | Result |
Worked example
= 2 m · = 3 m · = 30 °
= 1.33333 · Source: EN 1997-1:2004 Annex D
Scope and standard
Rectangular shallow foundations according to EN 1997-1, Annex D.
- Standard
- EN 1997-1:2004, clause D.4, Eq. (D.3)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Which value applies to my case?clarify the boundary conditions
- Limits and special caseswhen the formula does not apply
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Geotechnics › Bearing resistance.
Miaknows the formula catalog and asks for what is missing.