Design · Concrete

Curvature correction factor Kr

  • Type: Coefficient
  • Version 1
  • reviewed on 11/12/2026

Correction factor depending on axial load for nominal curvature method to EN 1992-1-1 Eq. (5.36).

Kr=min⁡(1.0,nu−nnu−nbal)\displaystyle K_{r} = \min\left(1.0, \frac{n_{u} - n}{n_{u} - n_{bal}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

nKr

Formula and quantities

SymbolNameUnitNote
nu\displaystyle n_{u}Ultimate relative axial force n_u = 1 + omega1
n\displaystyle nRelative axial force n = N_Ed / (A_c * f_cd)1
nbal\displaystyle n_{bal}Relative axial force at balanced moment capacity (typically 0.4)1
Kr\displaystyle K_{r}Curvature correction factor1Result

Worked example

nu\displaystyle n_{u} = 1.2 1 · n\displaystyle n = 0.6 1 · nbal\displaystyle n_{bal} = 0.4 1

Kr\displaystyle K_{r} = 0.75 1 · Source: EN 1992-1-1:2004 Eq. (5.36)

Scope and standard

Slender reinforced concrete columns to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 5.8.8.3 (3), Eq. (5.36)
Result
Kr\displaystyle K_{r} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Kr\displaystyle K_{r} = 0.75 1= min(1.0; ((1.2 1) - (0.6 1)) / ((1.2 1) - (0.4 1)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.