Design · Concrete
Fire design axial resistance of RC column (EN 1992-1-2)
Design axial compressive resistance of a reinforced concrete column in fire using the reduced concrete section according to EN 1992-1-2 Annex B.1: NRdfi = Acfi · fcdfi + As · fsdfi.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Reduced effective concrete cross-section area | mm² | ||
| Design compressive strength of concrete in fire | N/m² | ||
| Total area of longitudinal reinforcement | mm² | ||
| Design yield strength of reinforcement in fire | N/m² | ||
| Design axial resistance in fire | kN | Result |
Worked example
= 100,000 mm² · = 30,000,000 N/m² · = 2,400 mm² · = 300,000,000 N/m²
= 3,720 kN
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.