设计 · 混凝土
钢筋混凝土柱火灾下轴向设计承载力 (EN 1992-1-2)
根据 EN 1992-1-2 附录 B.1 采用折减混凝土截面的火灾下钢筋混凝土柱轴压设计承载力:NRdfi = Acfi · fcdfi + As · fsdfi。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 折减有效混凝土截面面积 | mm² | ||
| 火灾下混凝土抗压设计强度 | N/m² | ||
| 纵向钢筋总截面面积 | mm² | ||
| 火灾下钢筋设计屈服强度 | N/m² | ||
| 火灾下轴向设计承载力 | kN | Result |
实例
= 100,000 mm² · = 30,000,000 N/m² · = 2,400 mm² · = 300,000,000 N/m²
= 3,720 kN
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.