Design · Concrete
Span-to-depth steel stress modification factor F3
Modification factor for steel serviceability stress in allowable span-to-depth ratio to EN 1992-1-1 Clause 7.4.2 (2): F3 = 310 / σs.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Tensile stress in steel reinforcement under quasi-permanent load | N/m² | ||
| Steel stress modification factor | 1 | Result |
Worked example
= 250,000,000 N/m²
= 1.24 1 · Source: EN 1992-1-1:2004 clause 7.4.2 (2)
Scope and standard
Reinforced concrete beams and slabs to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 7.4.2 (2)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Which value applies to my case?clarify the boundary conditions
- Limits and special caseswhen the formula does not apply
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.