Design · Concrete
Strength reduction factor nu1 for cracked concrete struts
Strength reduction factor for concrete cracked in shear according to EN 1992-1-1: ν1 = 0.6 · (1 - fck / (250 MPa)).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic compressive strength | N/mm² | ||
| Strut strength reduction factor | – | Result |
Worked example
= 30 N/mm²
= 0.528 · Source: EN 1992-1-1:2004 Eq. (6.9)
Scope and standard
Reinforced concrete members designed using the variable strut inclination method (EN 1992-1-1, clause 6.2.3).
- Standard
- EN 1992-1-1:2004, clause 6.2.3 (3), Eq. (6.9)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Which value applies to my case?clarify the boundary conditions
- Limits and special caseswhen the formula does not apply
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.