Design · Concrete
Maximum longitudinal reinforcement area for beams
Maximum area of longitudinal reinforcement for concrete beams according to EN 1992-1-1: As,max = 0.04 · Ac.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Gross concrete cross-sectional area | m² | ||
| Maximum area of longitudinal reinforcement | m² | Result |
Worked example
= 0.15 m²
= 0.006 m² · Source: EN 1992-1-1:2004 clause 9.2.1.1 (3)
Scope and standard
Reinforced concrete beams outside lap locations according to EN 1992-1-1, clause 9.2.1.1 (3).
- Standard
- EN 1992-1-1:2004, clause 9.2.1.1 (3)
- Result
- in m²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.