Design · Composite

Composite column second-order critical load Ncr,eff (EN 1994-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Elastic critical buckling load of a composite column calculated with the second-order effective flexural stiffness EIeff,II according to EN 1994-1-1 Clause 6.7.3.4: Ncr,eff = π² · EIeff,II / L².

Ncr,eff=π2⋅EIeff,II/L2\displaystyle N_{\mathrm{cr},\mathrm{eff}} = \pi ^2 \cdot EI_{\mathrm{eff},II} / L^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NcreffL

Formula and quantities

SymbolNameUnitNote
EIeff,II\displaystyle EI_{\mathrm{eff},II}Effective second-order flexural stiffnesskN·m²
L\displaystyle LSystem buckling length of columnm
Ncr,eff\displaystyle N_{\mathrm{cr},\mathrm{eff}}Effective elastic critical loadkNResult

Worked examples

4.5 m composite column

EIeff,II\displaystyle EI_{\mathrm{eff},II} = 18,000 kN·m² · L\displaystyle L = 4.5 m

Ncr,eff\displaystyle N_{\mathrm{cr},\mathrm{eff}} = 8,772.98 kN

6.0 m composite column

EIeff,II\displaystyle EI_{\mathrm{eff},II} = 45,000 kN·m² · L\displaystyle L = 6 m

Ncr,eff\displaystyle N_{\mathrm{cr},\mathrm{eff}} = 12,337 kN

Standard and source

Standard
EN 1994-1-1:2004, clause 6.7.3.4
Result
Ncr,eff\displaystyle N_{\mathrm{cr},\mathrm{eff}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ncr,eff\displaystyle N_{\mathrm{cr},\mathrm{eff}} = 8,772.98 kN= pi² · (18,000 kN·m²) / (4.5 m)²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.