Design · Connections

Basic concrete cone breakout resistance NRk,c0 (EN 1992-4)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Characteristic concrete cone breakout resistance of a single uninfluenced fastener in tension according to EN 1992-4 Clause 7.2.1.4 Eq. (7.2): NRk,c0 = k1 · √(fck) · hef¹.5.

NRk,c0=k1⋅fck⋅hef1.5\displaystyle N_{Rk,c0} = k_{1} \cdot \sqrt{f_{ck}} \cdot h_{\mathrm{ef}}^1.5
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRkc0heffck

Formula and quantities

SymbolNameUnitNote
k1\displaystyle k_{1}Concrete cone factor (7.7 cracked, 11.0 uncracked post-installed)1
fck\displaystyle f_{ck}Characteristic cylinder compressive strength of concreteN/m²
hef\displaystyle h_{\mathrm{ef}}Effective embedment depth of fastenermm
NRk,c0\displaystyle N_{Rk,c0}Basic concrete cone resistancekNResult

Worked example

k1\displaystyle k_{1} = 7.7 · fck\displaystyle f_{ck} = 25,000,000 N/m² · hef\displaystyle h_{\mathrm{ef}} = 100 mm

NRk,c0\displaystyle N_{Rk,c0} = 38.5 kN

Standard and source

Standard
EN 1992-4:2018
Result
NRk,c0\displaystyle N_{Rk,c0} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRk,c0\displaystyle N_{Rk,c0} = 38.5 kN= (7.7 1) · sqrt((25,000,000 N/m²) / 1 [MPa]) · ((100 mm) / 1 [mm])¹.5 · 1 [N]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.