Design · Connections
Basic concrete blow-out resistance NRk,cb0 (EN 1992-4)
Basic characteristic concrete blow-out resistance for a deep headed fastener close to an edge according to EN 1992-4 Clause 7.2.1.8 Eq. (7.25): NRk,cb0 = k5 · c1 · √(Ah) · √(fck).
- EN 1992-4:2018
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Blow-out factor (8.7 cracked, 12.2 uncracked concrete) | 1 | ||
| Edge distance to nearest free edge | mm | ||
| Load-bearing area of fastener head | mm² | ||
| Characteristic cylinder compressive strength of concrete | N/m² | ||
| Basic concrete blow-out resistance | kN | Result |
Worked example
= 8.7 · = 80 mm · = 450 mm² · = 30,000,000 N/m²
= 80.8679 kN
Standard and source
- Standard
- EN 1992-4:2018
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.