Design · Connections

Basic combined pull-out resistance of bonded anchor NRk,p0 (EN 1992-4)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Basic characteristic combined pull-out and concrete failure resistance of a single bonded fastener according to EN 1992-4 Clause 7.2.1.6 Eq. (7.14): NRk,p0 = ψsus · τRk · π · d · hef.

NRk,p0=ψsus⋅τRk⋅π⋅d⋅hef\displaystyle N_{Rk,p0} = \psi _{sus} \cdot \tau _{Rk} \cdot \pi \cdot d \cdot h_{\mathrm{ef}}
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRkp0hefψsusτRk

Formula and quantities

SymbolNameUnitNote
ψsus\displaystyle \psi_{sus}Sustained load factor1
τRk\displaystyle \tau_{Rk}Characteristic bond resistance of adhesiveN/m²
d\displaystyle dNominal fastener diametermm
hef\displaystyle h_{\mathrm{ef}}Effective embedment depth of fastenermm
NRk,p0\displaystyle N_{Rk,p0}Basic bonded anchor pull-out resistancekNResult

Worked example

ψsus\displaystyle \psi_{sus} = 0.85 · τRk\displaystyle \tau_{Rk} = 8,500,000 N/m² · d\displaystyle d = 16 mm · hef\displaystyle h_{\mathrm{ef}} = 125 mm

NRk,p0\displaystyle N_{Rk,p0} = 45.396 kN

Standard and source

Standard
EN 1992-4:2018
Result
NRk,p0\displaystyle N_{Rk,p0} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRk,p0\displaystyle N_{Rk,p0} = 45.396 kN= (0.85 1) · (8,500,000 N/m²) · pi · (16 mm) · (125 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.