设计 · 砌体
空腔砌体墙有效厚度
拉结空腔墙的有效厚度:tef = cbrt(ktef · t1³ + t2³)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 弹性模量比 E_1 / E_2(上限 1.0) | – | > 0, ≤ 1 | |
| 外叶墙或非受荷叶墙厚度 | mm | > 0 | |
| 受荷内叶墙厚度 | mm | > 0 | |
| 空腔墙有效厚度 | mm | Result |
实例
= 1 · = 115 mm · = 175 mm
= 190.197 mm · Source: 手算
Scope and standard
EN 1996-1-1 第 5.5.1.3 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第5.5.1.3条,式(5.6)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.