設計 · 組積造構造
中空組積造壁の有効厚さ
つなぎ材で緊結された中空壁の有効厚さ:tef = cbrt(ktef · t1³ + t2³)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 弾性係数比 E_1 / E_2(上限 1.0) | – | > 0, ≤ 1 | |
| 外壁層または非載荷層の厚さ | mm | > 0 | |
| 載荷内壁層の厚さ | mm | > 0 | |
| 中空壁の有効厚さ | mm | Result |
例題
= 1 · = 115 mm · = 175 mm
= 190.197 mm · Source: 手計算
Scope and standard
EN 1996-1-1 条項 5.5.1.3.
- Standard
- EN 1996-1-1-2005-a1:2012、5.5.1.3項、式 (5.6)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.